The Florida Department of Transportation (FDOT) initiated the construction of the new Little Lake Harris Bridge with the intention of conforming the bridge to meet current safety standards. GRL Engineers, Inc. was brought onto the project in December 2017, for dynamic pile testing and related service, as the specialty consultant member of the design/build team for the piling work.
The current bridge over Little Lake Harris in Central Florida has been in use since 1950. The original bridge that connected Howey and Astatula was a long, wooden bridge that opened in 1927. After the second span was built, the wooden bridge was torn down, only leaving a small dock in its place. Being the third iteration of the pathway from Howey and Astatula, it is of significance that the new bridge can service the drivers of Lake County, Florida.
During the pile installations, GRL performed 100% testing with the Pile Driving Analyzer® (PDA) and analyzed the results of all 210 driven piles, PDA data was analyzed using CAPWAP® signal matching software. The data from these tests show that all project piles were driven to below the required minimum tip elevation, and achieved ultimate load bearing capacities. The test records of all piles do not contain characteristics that would indicate pile structural integrity issues.
For additional information, please read the entire Dynamic Pile Testing Case Study
The addition of a third structure, between the two existing bridge structures, carrying I-480 over...
When: September 23-24, 2014 The Pile Driving Analyzer® system (PDA) is the most widely employed...
Any structure is only as good as its foundation. For a deep foundation to perform satisfactorily, i...
When: April 12th, 2016 The Pile Driving Analyzer® system (PDA) is the most widely employed system f...
The Ohio Department of Transportation (ODOT) concurrently had funded a research project on large di...