GRL performed a bi-directional static load test ("BDSLT") and provided Thermal Integrity Profiling (TIP) during the reconstruction of Russell Street Bridge in Missoula.
The existing 2-lane Russell Street Bridge in Missoula, Montana, a major highway with high traffic volume, was in need of reconstruction. GRL was contacted to perform a bi-directional static load test ("BDSLT") on a representative test shaft. The test shaft had a diameter of 71 inches, and a length of 75 feet. The embedded bi-directional jack assembly contained three 2,200-kip GRL-Cells, resulting in a potential test load of 13,200 kips. GRL provided thermal integrity profiling ("TIP") services to assess concrete quality and post-concreted geometry of the test shaft. Six Thermal Wire® cables from Pile Dynamics, Inc. were installed full-depth on the reinforcing cage. The TIP data were used to compute effective average radii, and thereby develop a model of shaft cross-sectional area vs. depth. This model is integral to determining unit shaft resistance values from the BDSLT.
Other embedded instrumentation including strain gages, displacement transducers, and telltales provided information on structural and geotechnical foundation response to test loading. Test results included jack assembly bearing plates' displacements, internal force profiles, mobilized shaft and base resistances, foundation displacement, an equivalent top-loading curve, and an assessment of creep behavior. When applied to design values, resistances factors, and construction conditions encountered, these test results provided the basis for significant savings in foundation costs.
For additional information, please visit: Russell Street Bridge Replacement Case Study
Source: GRL engineers, inc.
GRL Engineers, Inc. recently completed two bi-directional static load tests (BDSLT) within a 24 hou...
The GRL-Cell is a high capacity device installed within a deep foundation to statically load test t...
The known vacation destination, Harbor Island, is accessed through this drawbridge, located on US-2...
Bi-Directional Load Testing with GRL-Cell Bi-Directional Load Testing is a high capacity static loa...
GRL performs both highly instrumented static load tests to meet the need of project design tests as...
The addition of a third structure, between the two existing bridge structures, carrying I-480 over...
GRL Engineers, Inc. has provided reliable testing for over 40 years in the deep foundations indust...
The expertise of GRL Engineers is key to selecting the right test for each situation. When it co...
Static Load Tests can be performed to validate foundation design assumptions regarding the axial co...