Static Load Tests can be performed to validate foundation design assumptions regarding the axial compression or axial tension resistance provided by a deep foundation element, or its deflected shape under a lateral load.
GRL performs both highly instrumented static load tests to meet the need of project design tests as well as basic load tests, for construction quality assurance. Depending on the project requirements, loading condition, and deep foundation type, GRL can attach or embed vibrating wire strain gages, resistance strain gages, vibrating wire piezometers, pressure cells, in-place inclinometer strings or ShapeAccelArrays. The readings from these devices are collected and stored on a multi-channel data logger.
Conventional readings of the applied load determined from the jack pressure gage and load cell, and deep foundation head movement determined by LVDTs, digital dial gages, or mechanical dial gages, can be combined with the instrumentation, mentioned above, to determine the capacity or nominal soil resistance, the load-transfer behavior under axial loads, or deflected shape under lateral loads.
After processing the collected load test data, GRL engineers prepare a final report summarizing the load-movement results.
Click here to read more about Static Load testing by GRL.
Source: GRL Engineers
GRL performs both highly instrumented static load tests to meet the need of project design tests as...
The Static Load Tester (SLT) joins Pile Dynamics’ extensive line of quality assurance and quality c...
The GRL-Cell is a high capacity device installed within a deep foundation to statically load test t...
Bi-Directional Load Testing with GRL-Cell Bi-Directional Load Testing is a high capacity static loa...
Performing a load test is the best way to confirm pile capacity. It confirms if the pile has the ca...
The addition of a third structure, between the two existing bridge structures, carrying I-480 over...
Static Load Testing (SLT) Static Load Testing (SLT) is used to evaluate the behavior of deep founda...
GRL Engineers, Inc. recently completed two bi-directional static load tests (BDSLT) within a 24 hou...
Helical pile installers and designers get this question all the time: “Do I need to do full scale l...