The I-480 Valley View Bridge project near Cleveland, Ohio involved the construction of a third bridge structure between two existing structures. The design-build team of Walsh Construction and CH2M (now Jacobs) developed the pile load test program and contracted GRL to perform the testing and analysis.
The test program’s goal was to optimize the driven pile foundations for 12 substructures and take advantage of significant soil set-up in the glacial silts and clays of the Cuyahoga River Valley. Soil set-up is an increase in soil resistance with time. The increase in soil resistance is due to soil remolding around the pile and pore water pressure dissipation after pile installation. While no exact amount of savings has been calculated, the new structure was completed with approximately 64,000 lineal feet (19,500 lineal meters) of piling in the 12 substructures and had 66,000 lineal feet (20,100 lineal meters) LESS than the existing structures. Furthermore, by only considering the end of drive soil resistance and ignoring soil set-up, it was estimated that an ADDITIONAL 105,000 lineal feet (32,000 lineal meters) of pile would have been required.
The pile test program included 24 test piles. The piles were tested during initial driving, short term restrikes, and long term restrikes. In addition, three static load tests were performed. The test piles were 18” (460mm) diameter, closed-end pipe piles installed with an ICE I-46 diesel hammer. Initial drive testing indicated significant variability in the soil resistance to driving across the site. Short term restrikes were performed using the I-46 hammer and were typically performed one to seven days after the pile was installed. Instrumented static load tests were performed at three pier locations across the site. The embedded instrumentation was used to evaluate the soil resistance distribution to relate to and compare with the CAPWAP analysis results for the other test piles in the program. Long term restrikes were performed 28 to 56 days after pile installation. Since the pile hammer could not mobilize the full soil resistance, the restrikes were performed using GRL’s APPLE 4 drop hammer utilizing a 28 ton drop weight. Soil set-up curves, consisting of quantified soil set-up vs. depth, were developed from the load test program data. Additional dynamic testing was performed at each pier during production driving. Short term restrikes were compared to the pile test program results and the performance of the production pile hammer was evaluated. Depth dependent driving criteria were established for each substructure using the test program and production dynamic test results, as well as Wave Equation analysis results using the GRLWEAP program. The deeper the pile was installed, the more soil set-up would occur, and therefore the target capacity at the end of driving, and the required blow count decreased. This method took full advantage of the soil set-up curves developed during the test program and the measured hammer performance during production pile driving.
This intensive design-phase pile test program saved significant time and money on the I-480 Valley View Bridge project.
Source: GRL's Newsletter: No 92_Details and Benefits of a Design-Phase Pile Test Program
The addition of a third structure, between the two existing bridge structures, carrying I-480 over...
Nominated for the Top Project Award, GRL Engineers, Inc., has been recognized for the contributions...
Helical pile installers and designers get this question all the time: “Do I need to do full scale l...
The only way to guarantee a pile will carry the load is with a load test. Learn about types of load...
Pile foundation is actually a slender column or long cylinder made of materials such as concrete...
The Ohio Department of Transportation (ODOT) concurrently had funded a research project on large di...
Any structure is only as good as its foundation. For a deep foundation to perform satisfactorily, i...
Learn how Geotechnical Engineers use valuable jobsite data to validate their recommendations for de...