This example demonstrates two basic internal checks for a 6.0 m high geogrid-reinforced soil wall: tensile rupture and reinforcement pullout. It is intentionally simplified, uses level granular backfill and does not represent a complete design.
Each check is evaluated at the layer where it is most critical rather than at an arbitrary layer. Tensile demand increases with depth, so the tensile check is taken at the deepest layer. Pullout capacity is governed by the anchorage length available behind the assumed failure plane, which is shortest near the crest, so the pullout check is taken at the shallowest layer. Both checks are compared against a stated required margin so that the reader can see how close each one is to controlling the design.
| Input | Value |
| Wall height, H | 6.0 m |
| Backfill unit weight, γ | 18 kN/m3 |
| Effective friction angle, φ′ | 34° |
| Cohesion, c′ | 0 kPa |
| Uniform surcharge (live), q | 10 kPa |
| Vertical reinforcement spacing, Sv | 0.60 m |
| Reinforcement length, L | 4.20 m = 0.70H |
| Ultimate tensile strength, Tult | 50 kN/m |
| Illustrative reduction factors | RFCR = 1.50; RFID = 1.10; RFD = 1.10 |
| Pullout resistance factor, F* | 0.67 tan φ′ = 0.452 |
| Scale correction factor, α | 0.80 (geogrid) |
| Reinforcement surfaces mobilised, C | 2 |
| Minimum anchorage length | 1.0 m |
| Required tensile margin | 1.30 |
| Required pullout margin | 1.50 |
The surcharge is treated as a live load. It is therefore included when computing demand, but excluded when computing pullout resistance, since a transient load that increases demand cannot be relied upon to increase anchorage. F* and α are default values used in the absence of product-specific pullout test data; both should be replaced by tested values where available.
Ten layers are placed at 0.60 m centres with the uppermost at z = 0.3 m and the lowest at z = 5.7 m. Positioning the layers at the mid-height of their tributary zones means every layer carries exactly Sv = 0.60 m of wall, with no half-tributary special case at the crest or the base, and the full 6.0 m height is accounted for.

Solution
For a vertical wall face, level backfill and no wall friction, the Rankine active coefficient is:
Unrounded values are carried through the calculations below and rounded only for reporting.
Consider the lowest layer, at below the crest. The vertical stress including surcharge is:
The tributary tensile force assigned to the layer is:
required ✓
The tensile check is satisfied with approximately 11 % margin over the required value. Because this is the deepest layer, no other layer is more critical in tension. In a formal design the governing code may apply additional material or resistance factors, and the reinforcement-to-facing connection must be verified separately.
The assumed failure surface is the Rankine plane through the toe, inclined at to the horizontal. This is the appropriate assumption for extensible (geosynthetic) reinforcement; a bilinear surface is used for inextensible reinforcement. At a depth , the horizontal distance from the facing to the plane is:
This distance is greatest near the crest, so the anchorage length behind the plane, , is shortest there. For the uppermost layer at :
minimum ✓
The demand at this layer, including the live surcharge, is:
The pullout resistance uses the effective overburden only, excluding the live surcharge:
required ✓
The uppermost layer therefore satisfies the pullout check, but with only about 17 % margin — appreciably tighter than the tensile check. This is why the crest layer must be the one tested. Note also that if the surcharge were included on both sides of the check, would cancel exactly between resistance and demand and the ratio would reduce to , i.e. a function of anchorage length alone. It is the exclusion of the live surcharge from the resistance side that makes the shallow layers genuinely critical.
Both ratios below are expressed on the same basis: unfactored resistance divided by demand, compared against the required margin. Applying the margin to the resistance before reporting a ratio would make the two checks appear more different than they are.
| Check | Demand (kN/m) | Resistance (kN/m) | Ratio | Required |
| Tensile rupture, z = 5.7 m | 19.10 | 27.55 | 1.44 | 1.30 |
| Pullout, z = 0.3 m | 2.61 | 4.57 | 1.75 | 1.50 |
Not a complete wall design: External sliding and bearing, global and compound stability, facing and connection capacity, deformation, drainage, foundation settlement, seismic effects, construction tolerances and project-specific partial factors remain to be checked.
From Product Property to Design Resistance Design begins by defining the problem, the governing lim...
A cantilever sheet pile wall supporting a 3.5 m deep excavation in dry sand (γdry = 15.3 kN/m³, φ′...
In this third, and last, article about pile foundations’ load-bearing capacity, we are going to...
Design for a cantilever retaining wall supporting 3.0 m of dry sand backfill. The wall has a 3.20...
Problem 7.1: Gravity Wall Rankine and Coulomb Methods For the retaining wall shown in the figure b...
Introduction A standard penetration test (SPT) is one of the most popular in-situ tests carrie...
Problem 9.1 A square footing of width 2.25m is founded at depth of 1.5m on a sand layer which has...
When analyzing a geotechnical problem, different design parameters are utilized depending on draine...
Introduction to Lateral Earth Pressure Soil, unlike a true fluid, exhibits both density and intern...